UPS DELPHYS GP
Energy Saving: high efficiency without compromise
- Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems
- Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions
- Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power 2.0 UPS ranges
Full-rated power: kW=kVA
- No power downgrading when supplying the latest generation of servers (leading or unity power factor)
- Real full power, according to IEC 62040: kW=kVA (unity power factor design) 25% more active power available compared to legacy UPS
- Suitable also for leading power factor loads down to 0.9 without apparent power derating
Significant cost-saving (TCO)
- Maximum energy saving thanks to 96% efficiency in true double conversion mode: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill
- Up to 99% efficiency with FAST ECOMODE
- UPS "self-paying" with energy saving
- Energy Saver mode for global efficiency improvement on parallel systems
- kW=kVA means maximum power available with the same UPS rating: no overdesign cost and therefore less €/kW
- Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier
- Battery configuration can be optimized, thanks to a very wide DC range
- Extended battery life and performance:
- long life battery
- very wide input voltage and frequency acceptance, without battery use
- EBS (Expert Battery System) charging management improves battery service life
- BCR (Battery Capacity Re-injection) removes the constraints of using an additional load bank for the battery discharge test: it consists in re-injecting the energy stored in the batteries to other applications
Parallel systems
To fulfil the most demanding needs for power supply availability, flexibility and the installation to be upgraded.
- Modular parallel configurations up to 4 MW, development without constraint
- Distributed or centralized bypass flexibility to ensure a perfect compatibility with the electrical infrastructure
- Twin channel architecture with Static Transfer Systems
- Distributed or shared battery for energy storage optimization on parallel systems
Standard electrical features
- Integrated maintenance bypass for single unit (and 1 1 system)
- Backfeed protection: detection circuit
- EBS (Expert Battery System) for battery management
- Redundant cooling
- Battery temperature sensor
Electrical options
- Seperated or common input mains
- External maintenance bypass
- Extended battery charger capability
- Shared battery
- Flywheel compatible
- Galvanic isolation transformer
- Backfeed isolation device
- ACS synchronization system
- BCR (Battery Capacity Re-injection)
- FAST ECOMODE
Standard communication features
- User-friendly multilingual interface with color graphic display
- 2 slots for communication options
- Ethernet connection (WEB/SNMP/email)
- USB port for event log access
Communication options
- Advanced server shutdown options for stand-alone and virtual servers
- 4 additional slots for communication options
- ADC interface (configurable voltage-free contacts)
- MODBUS TCP
- MODBUS RTU
- BACnet/IP interface
Remote monitoring service
- LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7
- Data centres
- Telecommunications
- Healthcare sector
- Service sector
- Infrastructure
- Industrial applications